AUTOMATIC POWER FACTOR CORRECTION SYSTEM


In view of penalties raised by the state electricity boards for low power factor and a constant rise in power tariff, it is imperative for the business-oriented establishments to install the apt system to avoid penalties and saving energy cost.

Existing electrical networks tend to fluctuate under heavy load and vary the power factor that causes huge penalties.

To save against power penalties, it is important for the establishment to install an ideal APFC System


PURPOSE:
Power Factor Improvement at Point of Common Coupling of Electrical Installation.

SALIENT FEATURES
Sheet Steel Cabinet, Free Standing Type.
Central Busbar configuration.
Fuse Free Power Circuit Design.
Self Diagnostic System.
Rupture Safe, Self Healing Capacitors.
Micro Processor based Control.
Resonance Warning Algorithm.
Damping Reactors..
Capacitor Duty Contactor.
Inbuilt Timers.
Automatic capacitor healthiness monitoring.

QUEST FOR ENGINEERING EXCELLENCE
Construction
Welded Frame / Sheet Steel Construction – Rugged.
7 Tank Process – Purity.
Powder Coating – Lasting Finish.

Components
FRAKO, Germany Capacitors:
Short Circuit, Rupture, Touch & Spillage Safe
High over load withstand capacity - 2 times rated current permanently & > 350 times rated current for inrush.
High Temperature withstand up to 60 Deg. Ambient.
Guaranteed Individual Voltage Harmonic Withstand Capability.

FRAKO, Germany Micro Processor based Relay – Smart & Intelligent Relay with:
High sensing accuracy
Harmonic sensing & Resonance monitoring features
Automatic characteristic adjustment for different loading pattern
Automatic phase sequence, C & K factor identification.

Capacitor Duty Contactor with pre insertion resistors & low bounce contactors for enhanced life.

Measurement:
Digital Metering – Fast Acting & Accurate.
Four Quadrant Measurement – Sensitive to Reverse Power.
Lowest Pick Up Current – Excellent Resolution

Control:
Group Control / Feeder Control Protection MCCB / MCB : Safe & Reliable.
Cyclic Switching – Uniform loading of all steps.
Kinked Characteristics – Enhanced performance under low load condition.

User Friendly:
Auto / Semi-Auto / Manual Operation Modes.
Auto Tuning – Fit & Forget.
Monitoring Defective Stages – Self diagnostic.
Optional GSM Communication – Time Saving.

Protection:
Voltage harmonic overload alarm – Prevents resonance.
Alarms for undercompensation, voltage & current circuit faults, capacitor faults & frequent switching contingencies – Total protection for Safe & Reliable System performance.

Benefits:
Reduction in M.D KVA charges.
Avoidance of P.F Penalty.
Availing P.F Incentives.
Lesser Break Down
Higher Productivity.
Enhanced Life of Electrical Components

Ranges
APFC – CONTACTOR SWITCHED
System Dimension ( in mm ) Maxm.Capacitor Configuration
Length Width Height
APFC / 3 – 37.5 KVAR 650 300 750 2 x 15.1 + 7.6
APFC / 4 – 52.5 KVAR 650 300 750 3 x 15.1 + 7.6
APFC / 5 – 67.5 KVAR 750 300 750 4 x 15.1 + 7.6
APFC / 6 – 82.5 KVAR 800 300 800 5 x 15.1 + 7.6
APFC / 6 – 90 KVAR 800 300 800 6 x 15.1
APFC / 4 – 100 KVAR 600 400 1800 4 x 25
APFC / 6 – 120 KVAR 600 400 1800 4 x 15.1 +2 x 30
APFC / 6 – 150 KVAR 1000 550 1500 2 x 15.1 + 4 x 30.2
APFC / 6 – 180 KVAR 1000 550 1500 6 x 30.2
APFC / 8 – 200 KVAR 1100 550 1500 8 x 25
APFC / 8 – 210 KVAR 1100 550 1500 2 x 15.1 + 6 x 30.2
APFC / 8 – 240 KVAR 1100 550 1500 8 x 30.2
APFC / 10 – 250 KVAR 1300 550 1500 10 x 25
APFC / 10 – 270 KVAR 1300 550 1500 2 x 15.1 + 8 x 30.2
APFC / 10 – 300 KVAR 1300 550 1500 10 x 30.2
APFC / 12 – 330 KVAR 1300 550 1500 2 x 15.1 + 10 x 30.2
APFC / 12 – 360 KVAR 1300 550 1500 12 x 30.2
APFC / 8 – 400 KVAR 1300 550 1500 8 x 50
APFC / 10 – 450 KVAR 1400 550 1800 8 x 50 + 2 x 25
APFC / 10 – 500 KVAR 1400 550 1800 10 x 50
APFC / 10 – 540 KVAR 1400 550 1800 8 x 60.2 + 2 x 30.2
APFC / 10 – 600 KVAR 1500 550 1800 10 x 60.2
APFC / 11 – 660 KVAR 1500 550 1800 11 x 60.2
APFC / 12 – 720 KVAR 1500 550 1800 12 x 60.2




Higher Capacities
Online Monitoring Facilities with GSM Communication
Online Monitoring Facilities with WEBSERVER-TCP / IP COMMUNICATION
can also be supplied on request


top