FRAKO Germany Power Capacitors enclosed in a Sheet Metal Enclosure with Busbar and Cable entry arrangement for easy cable connection.
CAPACITOR BANKS WITH PROTECTION MCB:
FRAKO Germany Power Capacitors along with MCB for Protection Purpose enclosed in a Sheet Metal Enclosure with Busbar and Cable entry arrangement for easy cable connection.
Capacitor application Breaker needs to have faster opening time to avoid restriking between the contacts. In the case of MCB, the opening time by the tripping mechanism is independent of the operation. The present generations MCBs are built-in with current limiting features, thus partially damping the inrush current.
APPLICATION: Capacitor Banks can be selected for the Load Centre with several inductive loads operated together where :
FRAKO Germany Power Capacitors along with MCB for protection purpose, Capacitor Duty Contactor and ON & OFF Push Buttons for Switching the Capacitors enclosed in a Sheet Metal Enclosure with Busbar and Cable entry arrangement for easy cable connection. Capacitor Duty Contactors The Contactors being the only moving Component, necessitates careful selection for this application to ensure longer life for these Contactors. Due to the characteristics of the capacitor operations and necessity to restrict the inrush current by using a suitable Damping Resistor which shall be in the circuit only for a short duration (during the in-rush current phenomena), a careful selection of the Capacitor Duty Contactors with built-in Damping Resistors is required, considering the Transformer Impedance and the number of Capacitors operating in parallel. Capacitor Duty Contactors, which has two sets of Contacts, one for restricting inrush current and other set is for continuous loading of the capacitors. This Capacitor Duty Contactor is specially designed with the Damping Resistance which restricts the inrush current. We will be using specially designed Capacitor Duty Contactors with Damping Resistors. These types of Contactors are different from standard contactors.
AUTO SWITCHED BANKED CAPACITORS FRAKO Germany Power Capacitors along with MCB for protection purpose, Capacitor Duty Contactor and ON & OFF Push Buttons, Auto Manual Selector Switch, Timers for Discharge Interlocks and Control Contactors for Switching ON & OFF the capacitors either in Auto Mode or in Manual Mode enclosed in a Sheet Metal Enclosure with Busbar and Cable entry arrangement for easy cable connection. In automatic switching, the capacitor Bank is switched through control contactor energized through the motor controls and switched after a fixed delay. The switching is done through capacitor duty contactors, and push buttons. APPLICATION
CAPACITOR BANK CONFIGURATION
MANUAL SWITCHED CAPACITOR BANK |
CONFIGURATION |
MANUAL SWITCHED CAPACITOR BANK WITH/ FRAKO HEAVY DUTY CAPACITOR |
MANUAL SWITCHED CAPACITOR BANK WITH FRAKO SUPER HEAVY DUTY CAPACITOR |
CAPACITOR |
CAPACITOR |
|
CAP 1M 10.0 |
1 x 10.0 – 440-DB |
1 x 10.0 - 440-DP |
CAP 1M 12.5 |
1 x 12.5 – 440-DB |
1 x 12.5 - 440-DP |
CAP 1M 15.0 |
1 x 15.0 – 440-DB |
1 x 15.0 - 440-DP |
CAP 1M 25.0 |
1 x 25.0 – 440-DB |
1 x 25.0 - 440-DP |
CAP 1M 30.0 |
1 x 30.0 – 440-DB |
1 x 30.0 - 440-DP |
CAP 2M 10.0 |
2 x 10.0 – 440-DB |
2 x 10.0 - 440-DP |
CAP 2M 12.5 |
2 x 12.5 – 440-DB |
2 x 12.5 - 440-DP |
CAP 2M 15.0 |
2 x 15.0 – 440-DB |
2 x 15.0 - 440-DP |
CAP 2M 25.0 |
2 x 25.0 – 440-DB |
2 x 25.0 - 440-DP |
CAP 2M 30.0 |
2 X 30.0 – 440-DB |
2 X 30.0 - 440-DP |
AUTO SWITCHED CAPACITOR BANK
| CONFIGURATION | AUTO SWITCHED CAPACITOR BANK WITH FRAKO HEAVY DUTY CAPACITOR | AUTO SWITCHED CAPACITOR BANK WITH FRAKO SUPER HEAVY DUTY CAPACITOR |
| CAPACITOR | CAPACITOR | |
CAP 1A 10.0 |
1 x 10.0 – 440-DB |
1 x 10.0 - 440-DP |
CAP 1A 12.5 |
1 x 12.5 – 440-DB |
1 x 12.5 - 440-DP |
CAP 1A 15.0 |
1 x 15.0 – 440-DB |
1 x 15.0 - 440-DP |
CAP 1A 25.0 |
1 x 25.0 – 440-DB |
1 x 25.0 - 440-DP |
CAP 1A 30.0 |
1 x 30.0 – 440-DB |
1 x 30.0 - 440-DP |
CAP 2A 10.0 |
2 x 10.0 – 440-DB |
2 x 10.0 - 440-DP |
CAP 2A 12.5 |
2 x 12.5 – 440-DB |
2 x 12.5 - 440-DP |
CAP 2A 15.0 |
2 x 15.0 – 440-DB |
2 x 15.0 - 440-DP |
CAP 2A 25.0 |
2 x 25.0 – 440-DB |
2 x 25.0 - 440-DP |
CAP 2A 30.0 |
2 x 30.0 – 440-DB |
2 x 30.0 - 440-DP |