DYNAMIC POWER FACTOR CORRECTION SYSTEM


BARON POWER LTD., a leading resource for Power Quality Products & Services, offers Dynamic Power Factor Correction Systems ideally suitable for highly fluctuating Load applications.

PURPOSE:
Power Factor Improvement at installations with Fluctuating Loads.

SALIENT FEATURES
Sheet Steel Cabinet, Free Standing Type.
Central Busbar configuration.
Fuse Free Power Circuit Design.
Self Diagnostic System.
Rupture Safe, Self Healing Capacitors.
Micro Processor based Control.
Resonance Warning Algorithm.
Current Limiting Reactors.
High Speed Thyristor Switches.
Excellent Heat Transfer.
Inbuilt Timers.
Automatic capacitor healthiness monitoring.

QUEST FOR ENGINEERING EXCELLENCE
Construction
Welded Frame / Sheet Steel Construction – Rugged.
7 Tank Process – Purity.
Powder Coating – Lasting Finish.
Components
Germany Capacitors:
Short Circuit, Rupture, Touch & Spillage Safe
High over load withstand capacity - 2 times rated current permanently & > 300 times rated current for inrush.
High Temperature withstand up to 60 Deg. Ambient.
Guaranteed Individual Voltage Harmonic Withstand Capability.

BARON Micro Processor based Relay – Smart & Intelligent Relay with:
High sensing accuracy
Harmonic sensing & Resonance monitoring features
Automatic characteristic adjustment for different loading pattern
Automatic phase sequence, C & K factor identification.

Thyristor Switches to controll the capacitors and to compensate the reactive power dynamically. Additional they have protection / alarm features with di/dt limiting reactors for enhanced reliability of thyristors.

Thyristor Switch Assembly – Large heat sink, efficient heat transfer, high peak inverse voltage & opto coupled trigger circuit


Measurement:
Digital Metering – Fast Acting & Accurate.
Four Quadrant Measurement – Sensitive to Reverse Power.
Lowest Pick Up Current – Excellent Resolution

Control:
Group Control / Feeder Control Protection MCCB / MCB : Safe & Reliable.
Cyclic Switching – Uniform loading of all steps.

User Friendly:
Auto / Manual Operation Modes.
Auto Tuning – Fit & Forget.
Monitoring Defective Stages – Self diagnostic.
Optional GSM Communication – Time Saving.

Protection:
Ventilator control.
Alarms for low voltage, over voltage, low current, high current, undercompensation, insufficient capacitor power, supply of real power, harmonic threshold, overtemperature. – Total protection for Safe & Reliable System performance.

Benefits:
Reduction in M.D KVA charges.
Avoidance of P.F Penalty.
Availing P.F Incentives.
Lesser Break Down
Higher Productivity.
Enhanced Life of Electrical Components

Ranges
DYNAMIC APFC SYSTEM – THYRISTOR SWITCHED
System Dimension ( in mm ) Maxm.Capacitor Configuration
Length Width Height
DPFC/50 600 450 1275 25 X 1 + 12.1X 2
DPFC/75 600 450 1275 25 X 2+12.1 X 2
DPFC/100 1000 450 1275 25 x 4
DPFC/150 1000 450 1575 3 X 50
DPFC/200 1100 450 2075 3 X 50 + 2 X 25
DPFC/250 1200 450 2075 5 X 50
DPFC/300 1800 450 1575 6 X 50
DPFC/350 1800 450 1475 3 X 100 + 1 X 50
DPFC/400 1800 450 1875 3 X 100+ 2 X 50
DPFC/450 1800 450 1875 4 X 100+ 1 X 50
DPFC/500 1800 450 1875 4 X 100+ 2 X 50
DPFC/550 1800 450 2175 5 X 500+ 1 X 50
DPFC/600 1800 450 2175 5 X 100+ 2 X 50




Higher Capacities
Online Monitoring Facilities with GSM Communication
Online Monitoring Facilities with WEBSERVER-TCP / IP COMMUNICATION
can also be supplied on request