BARON POWER LTD., a leading resource for Power Quality Products & Services, specialize in Harmonic Filter Systems customized to meet specific performance expectations at Electrical installations.
PURPOSE:
Power Factor Improvement in harmonic environment.
Controlled Harmonic Current Management.
SALIENT FEATURES
Sheet Steel Cabinet, Free Standing Type.
Central Busbar configuration.
Fuse Free Power Circuit Design.
Self Diagnostic System.
Rupture Safe, Self Healing Capacitors.
Micro Processor based Control.
Anti Resonant.
Compact Filter Reactors.
Low bounce Contactors.
Inbuilt Timers.
Automatic capacitor healthiness monitoring.
Construction:
Welded Frame / Sheet Steel Construction – Rugged.
7 Tank Process – Purity.
Powder Coating – Lasting Finish.
Components
FRAKO, Germany Capacitors:
Short Circuit, Rupture, Touch & Spillage Safe.
High over load withstand capacity - 2 times rated current permanently & > 300 times rated current for inrush.
High Temperature withstand up to 60 Deg. Ambient.
525 Volts rated Capacitors – for reliable operation.
Guaranteed Individual Voltage Harmonic Withstand Capability
Automatic characteristic adjustment for different loading pattern
Automatic phase sequence, C & K factor identification.
Filter Duty Contactor – Low bounce Main contacts built with special alloy material for thermal withstanding characteristics.
FRAKO, Germany Harmonic Filter Reactor with:
Built-in harmonic overload capacity
Class “H” Insulation
Thermal Stability
Customized Tuning options.
Reduces losses and overloading of capacitors is avoided.Improvement of impedance behaviour of the mains.
Control:
Group Control / Feeder Control Protection MCCB / MCB: Safe & Reliable.
Cyclic Switching – Uniform loading of all steps.
Kinked Characteristics – Enhanced performance under low load condition.
User Friendly:
Auto / Semi-Auto / Manual Operation Modes.
Auto Tuning – Fit & Forget.
Monitoring Defective Stages – Self diagnostic.
Optional GSM Communication – Time Saving.
Protection:
Voltage harmonic overload alarm – Prevents resonance.
Alarms for undercompensation, voltage & current circuit faults, capacitor faults & frequent switching contingencies – Total protection for Safe & Reliable System performance.
Benefits:
Reduces Total Harmonic Distortion.
Reduces System Losses.
Improves Peak Phase & Average Phase Current.
Reduces Transformer Overloading.
Improves Phase Current & Voltage Balance.
Improves Power Factor of non-linear loads
Ranges
DE-TUNED HARMONIC FILTER SYSTEM – CONTACTOR SWITCHED
System
Dimension ( in mm )
Maxm.Capacitor Configuration
Length
Width
Height
ADHF/3 – 80 KVAR
600
550
1700
2 x 20+ 1 x 40
ADHF/3 – 120 KVAR
600
550
1700
3 x 40
ADHF/4 – 160 KVAR
600
550
1700
4 x 40
ADHF/4 – 200 KVAR
600
650
1700
3 x 40 + 1 x 80
ADHF/4 – 240 KVAR
1000
550
2175
2 x 40 + 2 x 80
ADHF/6 – 320 KVAR
1200
550
2175
4 x 40 + 2 x 80
ADHF/6 – 400 KVAR
1200
550
2175
2 x 40 + 4 x 80
ADHF/8 – 480 KVAR
1500
550
2175
4 x 40 + 4 x 80
ADHF/8 – 560 KVAR
1500
550
2175
2 x 40 + 6 x 80
ADHF/10 – 640 KVAR
1800
550
2175
4 x 40 + 6 x 80
ADHF/10 – 720 KVAR
1800
550
2175
2 x 40 + 8 x 80
ADHF/12 – 800 KVAR
1800
550
2175
4 x 40 + 8 x 80
ADHF/12 – 880 KVAR
1800
550
2175
2 x 40 + 10 x 80
ADHF/12 – 960 KVAR
1800
550
2175
12 x 80
Higher Capacities
Thyristor Switched (instead of Contactor) System
Online Monitoring Facilities with GSM Communication
Online Monitoring Facilities with WEBSERVER-TCP / IP COMMUNICATION can also be supplied on request
AUTO SWITCHED HARMONIC FILTER SYSTEM – CONTACTOR SWITCHED
System
Dimension ( in mm )
Maxm.Capacitor Configuration
Length
Width
Height
ASHF/2 – 80 KVAR
600
550
1700
2 x 20+ 1 x 40
ASHF/3 – 120 KVAR
600
550
1700
3 x 40
ASHF/2 – 160 KVAR
600
550
1700
4 x 40
ASHF/3 – 200 KVAR
600
650
1700
3 x 40 + 1 x 80
ASHF/3 – 240 KVAR
1000
550
2175
2 x 40 + 2 x 80
ASHF/4 - 320 KVAR
1200
550
2175
4 x 40 + 2 x 80
ASHF/5 – 400 KVAR
1200
550
2175
2 x 40 + 4 x 80
ASHF/6 – 480 KVAR
1200
550
2175
4 x 40 + 4 x 80
ASHF/7 – 560 KVAR
1500
550
2175
2 x 40 + 6 x 80
ASHF/8 – 640 KVAR
1500
550
2175
4 x 40 + 6 x 80
ASHF/9 – 720 KVAR
1800
550
2175
2 x 40 + 8 x 80
ASHF/10 – 800 KVAR
1800
550
2175
4 x 40 + 8 x 80
ASHF/11 – 880 KVAR
1800
550
2175
2 x 40 + 10 x 80
ASHF/12 – 960 KVAR
1800
550
2175
12 x 80
Higher Capacities
Thyristor Switched (instead of Contactor) System
Online Monitoring Facilities with GSM Communication
Online Monitoring Facilities with WEBSERVER-TCP / IP COMMUNICATION can also be supplied on request