| DESCRIPTION |
|
Simple Commissioning by automatic identification of threshold current (c/k value), phase angle, connected capacitor stages and switching sequences. |
|
Continuous Monitoring and display of Harmonic Voltage Levels. In the event of harmonic levels exceeding programmable limits, all capacitors will be switched off through overcurrent alarm |
|
Counts, Stores and Displays the number of switching operations for each Individual Capacitor Stage and alarm is triggered, if the switching counter exceeds the programmable limits. |
|
RMS current monitoring function provides excellent protection for capacitor banks without harmonic filters, especially when resonance cause an increase in harmonic levels. |
|
Enhanced Equipment life through : |
 |
Cyclic switching of capacitor stages of same rating, |
 |
Accurate switching of capacitor stages, preventing unnecessary switching for responsive control & |
 |
Continuous optimization of switching delay according to the required
reactive current. |

|
Potential-free alarm contact. |
 |
Programmable overcurrent alarm threshold limit (from 1.05 to 3.0 x Irms) |
|
Continuous monitoring for defective capacitor stages through self adjustment of control program. |

|
Zero Voltage and Zero Current tripping with alarm signal. |
|
Kinked Control curve characteristics to avoid overcompensation under light load condition. |
|
Four Quadrant Power control with LED display when active power is generated into mains. |
|
Manual / automatic operation to switch ON & OFF each Individual capacitor stages. |
|
Preset up to three fixed capacitor stages, excluded from normal automatic operation. |
|
Independent setting of capacitor switching time to match discharge time of capacitor stages. |

|
Suitable for current transformers with rated secondary current of 1 Amps or
5 Amps.
|

|
Clear digital display of key momentary values and operating parameters :
|
 |
Power Factor, |
 |
Apparent, Active & Reactive Currents, |
 |
5th, 7th, 11th & 13th harmonic voltage content & |
 |
Total capacitive power required to meet target power factor setting. |

|
|
 |
Undercompensation, |
 |
High harmonic levels, |
 |
Overcurrent, |
 |
Switching Counters, |
 |
Fault in Voltage Circuit ( U=0 alarm ), |
 |
Fault in Current Circuit ( I=0 alarm ) & |
 |
Fault in Capacitor Stages (C=0 alarm). |
|
Optional extension of the EMR 1100S to EMR 1100 full version by means of
software updating enables:
Potential Free Tariff Switching contact to select Dual Power Factor Setting, Remote indication of measuring values via RS 232 interface & historical data Communication with Building control systems. |